Bacteriostatic Water for HCG Injections

Bacteriostatic Water for HCG Injections

Bacteriostatic water for hcg injections USP is a sterile, non-pyrogenic, sterile preparation of water with 0.9% (9 mg/ml) or 1.1% (11 mg /ml) of benzyl alcohol as an added preservative. This type of preparation allows for repeated withdrawals of water from a single 10 ml vial of bacteriostatic water that comes in the HCG kit. Bacteriostatic water is different from sterile water. Sterile water is usually filtered and purified but has no additives. It’s for single use only.

Benzyl alcohol stops the growth of bacteria. It is a natural compound made from plants, therefore it’s safe to use. The safe packaging of Bac water is made of a semi-rigid vial specially formulated with a copolymer of ethylene and propylene. It requires no vapor barriers to keep a correct volume.

Indication and uses of BAC water

A bacteriostatic agent is a chemical agent that stops bacteria from reproducing while not necessarily killing them. BAC water can be used for a broader array of drug dilution for intravenous, intramuscular, or subcutaneous injection including the HCG hormone. Sterile Bac water used for HCG injection contains no bacteria. Bacteria can’t grow and reproduce in Bac water or act as an infectious agent, and so, it can be used repeatedly. In most cases, you can use bacteriostatic water for 28 days after opening. After that, you must discard the vial.

You can use bacteriostatic water in three different ways:

  1. Intramuscular injection: They deliver deep into the muscle for the bloodstream to absorb.
  2. Intravenous injection: They are sent directly into your vein using a needle or tube.
  3. Subcutaneous injection: It means under the skin.

How to use BAC water for HCG injection

Bacteriostatic water is essential in the reconstitution of HCG or human chorionic gonadotrophin hormone on the HCG diet.

  1. Using a mixing syringe, draw 5 ml of bacteriostatic water in the 10 ml vial. Be sure that you wipe the top of the vial clean first with an alcohol swab that comes along with the kit. Also, wipe the top of the vial that contains the HCG of 5000iu.
  2. Inject the bac water at the side of the HCG vial. Do not inject directly at the powder.
  3. Gently swirl the vial until the solution is clear. Do not shake it. Once the HCG powder and Bac water are evenly mixed, keep the vial refrigerated at all times.

Can I use sterile water in mixing the HCG?

Sterile water can be great for some things but the recommended means in reconstituting the HCG powder is bacteriostatic water. Bac water allows for repeated withdrawals of the mixture, and you can use them for up to 28 days once opened. Sterile water is for single-dose mixing only.

ADDRESS

26 Pacific Grove. United state (US) California 93950

Call Us (Tolls Free)

877-334-8709

EMAIL US HERE

support@www.hcg-injections.com

We offer everything you need to start, along with ongoing support for HCG Kits users, including tips, advice, and resources for a fitter, slimmer you!

Important Note:

Not everybody will react to in the same way to hCG (Human Chorionic Gonaditropin) – in other words what is true for one person might not work for another- as such do not get discourage if you don’t see the same pronounced results as in others on the same hCG diet – all the information provided here is based on people’s testimony and documentation gather from reputable sources online – the before and after pictures are submitted from our most successful customers and they were offered 20% discount incentive to show the very positive results – not everyone will achieve this – This being said the hCG diet works well , give it a try and see for yourself.

Our Payment Partners :

Add to cart